12.2.7.2
Remote Controller Wiring
Tank Unit
Remote Controller w
(field supply)
Terminal for Remote Controller wiring
Remote Controller cable shall be (2 x min
0.3 mm
2
), of double insulation PVC-sheathed or
rubber sheathed cable. Total cable length shall be
50 m or less.
Be careful not to connect cables to other terminals
of Tank Unit (e.g. power source wiring terminal).
Malfunction may occur.
Do not bundle together with the power source
wiring or store in the same metal tube. Operation
error may occur.
12.2.7.3
Remove The Remote Controller
From Tank Unit
Remove the top case from the bottom case.
Remove the wiring between Remote controller
and Tank Unit terminal.
Claw
(2 places)
Disconnect the
Remote controller
wiring
Remote Controller
iring
No polarity
Insert the
driver and
slightly turn.
Flat-blade
screwdriver
Bottom
case
12.2.7.4
For exposed type
Preparation: Make 2 holes for screws using a driver.
Mount the top case.
Align the claws of the top
1
case and then align the claws
of the bottom case.
2
Connect the remote control
wiring
Arrange the wires along the groove
of the case.
For embedded type
Preparation: Make 2 holes for screws using a driver.
Mount the top case.
Align the claws of the top
case and then align the claws
of the bottom case.
Avoid the wire
being caught.
Connect the remote
control wiring
77
Mounting The Remote
Controller
Mount the bottom case to
the wall.
Cut here with
a nipper and
remove the burr
with a file.
U P
Claw (2 places)
Hole for screw
Claw (2 places)
Screw
(field supply)
Pass through
Remote controller terminal board
Remove the coating. Approx. 6 mm
Top case
(Back side)
Bottom case
(Back side)
Remove the sheath. Approx. 180 mm.
Make sure the wiring connection is in the
correct direction.
Mount the bottom case
to the wall.
Pass the wire through the hole
in the centre of the bottom case.
U P
Claw (2 places)
Hole for
screw
Claw (2 places)
Screw
(field supply)
Top case
(Back side)
Bottom case
(Back side)
Wall to which
the remote
controller
is
fixed
Clamper
(field supply)
the hole
Remote controller
terminal board
Remove the coating.
Approx. 6 mm
Make sure the wiring
connection is in the correct
direction.