Panasonic WH-UD05JE5 Service Manual page 109

Air-to-water hydromodule + tank
Hide thumbs Also See for WH-UD05JE5:
Table of Contents

Advertisement

12.4.3.5
Service Setup
34. Pump maximum speed
Normally setting is not necessary.
Please adjust when need to reduce the pump sound etc.
Besides that, it has Air Purge function.
When *Pump flow setting is Max. Duty, this duty set is the fix pump duty run
during room side operation.
35. Pump down
Operate pump down operation
36. Dry concrete
Operate concrete curing operation.
Select Edit, set temp for every stage (1~99 1 is for 1 day).
Setting range is 25~55°C
When it is turned ON, dry concrete starts.
When it is 2 zone, it dries both zones.
37. Service contact
Able to set name & tel no. of contact
person when there is breakdown
etc. or client has trouble. (2 items)
Initial setting: Depend on model
Service setup
Pump down:
ON
Confirm
30°C
Service setup
Service contact:
Contact 1
Contact 2
Select
Confirm
Service setup
Flow rate
88:8 L/min
Select
12:00am,Mon
Service setup
Pump down:
45°C
40°C
40°C
35°C
1
2
3
5
4
12:00am,Mon
Contact-1: Bryan Adams
ABC/ abc
A B C D E F G H I J K L M N O P Q R
S T U V W X Y Z
j k l m n o p q r s t u v w x y z
Select
109
12:00am,Mon
Max. Duty
Operation
Air Purge
0xCE
17:26, Wed
Pump down operation
in progress!
ON
OFF
Confi rm
35°C
6
Stage
0-9/ Other
a b c d e f g h i
Enter