Panasonic WH-UD05JE5 Service Manual page 45

Air-to-water hydromodule + tank
Hide thumbs Also See for WH-UD05JE5:
Table of Contents

Advertisement

Menu
7 Installer setup Service setup
Pump maximum speed
7.1
To set the maximum speed of
the pump.
Default Setting
Setting Options / Display
Tank heat up time (max)
Maximum time for
1:00
heating the tank
(in hours and minutes)
Tank re-heat temp.
Set temperature to
-8 °C
perform reboil of tank
water.
Sterilization
Sterilization may be
set for 1 or more days
of the week.
Monday
Sun / Mon / Tue /
Wed / Thu / Fri / Sat
Sterilization: Time
Time of the selected
day(s) of the week to
sterilize the tank
12:00
0:00 ~ 23:59
Sterilization: Boiling temp.
Set boiling
65 °C
temperatures for
sterilize the tank.
Sterilization: Ope. time (max)
Set sterilizing time
0:10
(in hours and minutes)
Setting the flow rate, max. duty and operation
ON/OFF of the pump.
Flow rate: XX:X L/min
Max. Duty: 0x40 ~ 0xFE,
Pump: ON/OFF/Air Purge
45