Dpv1 Error Codes - Beckhoff FC3102 Documentation

For profibus
Table of Contents

Advertisement

Byte
Meaning
0
Header byte = 0x83 (3 bytes including header, bits 6,7 = 2)
1
Bits 0-5: Channel number
Bits 6-7: 0 = reserved, 1 = input, 2 = output, 3 = input/output
2
Bits 0-4: Error type
Bits 5-7: Channel type
Error type
Value
Meaning
0
reserved
1
Short circuit
2
Undervoltage
3
Overvoltage
4
Overload
5
Overtemperature
6
Wire breakage
7
Upper limit value exceeded
8
Value below lower limit
9
Error
10-15
reserved
16-31
Manufacturer specific (see the documentation for the DP slave)
Channel type
Value
Meaning
0
Any type
1
Bit
2
2 bit
3
4 bit
4
Byte
5
Word
6
2 words
7
reserved
Revision number
The structure of the revision number may be found in the documentation for the DP slave.
5.1.1

DPV1 Error Codes

In the event of an incorrect DPV1 access, the slave replies with 4 bytes of data (any values that are not
described here are not defined in the DPV1 standard, and are therefore to be found in the slave's manual):
Byte 0
0xD1
0xD7
0xDE
0xDF
FC3101 and FC3102
DPV1 service
Data_Transport
Initiate
Read
Write
Version: 3.0
Appendix
71