Uploading The Configuration - Beckhoff FC3102 Documentation

For profibus
Table of Contents

Advertisement

FC310x as master
ADS-Write parameters
Net-ID
Port
IndexGroup
IndexOffset
Length
Data
Abort parameter
0x00
0x01 - 0x02
3.6.3

Uploading the Configuration

The PROFIBUS can be scanned by ADS [} 28] Read for new devices during operation:
ADS-Read parameters
Net-ID
Port
IndexGroup
IndexOffset
Length
Data
If the IndexGroup indicates that, for Beckhoff devices, tables 0, 1 and 9 are to be read, then the following
data is supplied, provided the device is a Beckhoff device:
Offset
0 -1
2 -513
514 - 1025
1026 - 1537
If the device is from another manufacturer, or if the IndexGroup indicates that Beckhoff devices are to
behave in exactly the same way as devices from other manufacturers, then the following information is
returned in the ADS read response:
Offset
0 -1
2 - 7
8 - 251
34
Meaning
Net-ID of the master (see the device's ADS [} 44] tab)
0x1000 + station address of the slave
0x400 + slot number (DPV1 parameter)
0
Length of the Abort parameter (3)
In request: Abort parameter
Reason_Code
Additional_Detail
Meaning
Net-ID of the master (see the device's ADS [} 44] tab)
200
0xzzyyF830 (yy = station address, zz = 0: for Beckhoff devices, tables 0,1 and 9
are read, zz = 0x80: Beckhoff devices provide the same information as third-
party devices)
0
1538
Configuration data of the slave
Description
0
Table 0. Amongst the information contained here is the precise coupler type and
the firmware version
Table 9 (includes the coupler number and the terminal numbers)
Table 1 (only relevant for bus controllers. The assignment of the terminals is
part of the information contained here)
Description
1
DP diagnostic data bytes 0-5 (see Slave Diagnostics [} 23])
DP configuration data (CfgData [} 73])
Version: 3.0
FC3101 and FC3102

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fc3101