Problem
LAYOUT MODE
No dots or poor dots in Layout
and Marking Mode.
3A6466A Operation, Repair, Parts
Cause
Too small of Dot setting.
Gun is not activated.
Cable is not adjusted properly.
Tip clog.
Battery voltage is too low.
Solution
Increase Dot size, page 35.
Press the 1 or 2 button on control to activate a
gun.
Adjust Cable to properly actuate gun trigger,
page 23.
Clear tip or Replace tip.
Charge battery or replace battery.