Ttl Weigand Output; Data Byte (Sr505 Only) - IDTECK 505R Series Manual

Door controller with a dual 8bit microprocessor
Table of Contents

Advertisement

2.14

TTL WEIGAND Output

This function allows whether to use "TTL Output" as "WEIGAND Output"
The default value is "NOT USE"
You can select setup status by using "<4> or <6>" keys
If you press "ENTER" after choosing "TTL WEIGAND" to "USE", TTL,1,2 setup values
would be initialized to "00".
2.15

Data Byte (SR505 Only)

This feature only applies to the SR505.
By default, the SR505 can read smart card written in the 4BYTE format, but, for advanced a
pplications, you can use 2BYTE format smart cards. To do so, you must change the Data BYT
E setting to "2BYTE". To change the setting, press <ENT> and press <4> or <6> to select "4BY
TE" or "2BYTE" and press <ENT> to confirm.
4 Byte (Default)
The Card Number can be in the ranges of 00000000 – 4294967295.
2 Byte
The first and last 5 digits can each be in the ranges of 00000 ~ 65535, respectively.
The total is in the ranges of 0000000000~6553565535
Setup Menu F2