2.7

Anti-Passback

The Anti-Pass Back feature is used to prevent an identical user from entering or exiting the d
oor more than twice in a row so that employees cannot pass back their cards to their cowor
kers. Anti-Pass Back can be applied only when an Exit Reader is installed. "DO NOT" enable it
if an "Exit Button" is installed instead of an Exit Reader.
For enable or disable Anti-Pass Back or resetting all APB flags, press <ENT> and press <4> or
<6> to select the desired item and press <ENT> to confirm.
DISABLE
The Anti-Pass Back feature is disabled.
ENABLE
The Anti-Pass Back feature is enabled.
ALL CLEAR!
All Anti-Pass Back flags are reset, and access will be allowed one time regardless of th
e current status of the existing flags.
2.8

RF PIN Input

RF Pin Input allows you to decide whether to enable or disable PIN (or RF card number) Inpu
t via the keypad. By default, PIN Input is disabled.
Setup Menu F2
p.59