Rev. 1.3
5.2 Total View / Description
3
5
1
Basic housing
2
Nozzle with air cap and retaining ring
3
Raster needle lock
4
Material connection
5
Atomizer air connection
Control air connection – open control air
6
Control air connection – close control air
7
2x fastening threads M5 (optional with center-sagging and centering bush for well-positioned installa-
8
tion)
9
Connection pressure sensor, optional (on top or on the right when looking in spray direction)
5.3 Wiring Layout (separate control unit)
Assembly Instructions - Spray Valve SMS-22
1
9
7
6
Control unit not included
in scope of delivery
Walther Systemtechnik GmbH – D 76726 Germersheim
Telefon: +49 (0)7274-7022-0 Telefax: +49 (0)7274-7022-91
http://www.walther-2000.de – info@walther-2000.de
Page 9 of 25
2
8
4