Debit - Credit System With Connection To The Interface - Wega Wegaconcept Use And Maintenance Manual

Table of Contents

Advertisement

Wegaconcept
Beverages selection codes table
Description
Signal
1 Espresso GR1
011 h
1 Medium GR1
012 h
1 Large GR1
013 h
2 Espressos GR1
014 h
2 Medium GR1
015 h
2 Large GR1
016 h
1 Espresso GR2
021 h
1 Medium GR2
022 h
1 Large GR2
023 h
2 Espressos GR2
024 h
2 Medium GR2
025 h
2 Large GR2
026 h
1 Espresso GR3
031 h
1 Medium GR3
032 h
1 Large GR3
033 h
2 Espressos GR3
034 h
2 Medium GR3
035 h
2 Large GR3
036 h
1 Espresso GR4
041 h
1 Medium GR4
042 h
1 Large GR4
043 h
2 Espressos GR4
044 h
2 Medium GR4
045 h
2 Large GR4
046 h
Tea 1
051 h
Tea 2
052 h
35.3
DEBIT - CREDIT system with
connection to the INTERFACE
The DEBIT-CREDIT system allows beverages to be
paid for after they have been delivered, as the doses
are recorded by the coffee machine's cash register. The
procedure is possible thanks to the interface between
the coffee machine and the cash register.
In particular, the system is structured as follows:
72
Beverages are delivered
by the coffee machine.
I/O Interface
Beverage deliveries are
recorded by the
cash register.
Installation
The CREDIT-DEBIT function is available on electronic
control units with software program dated 06/03/08 or
later.
For installation proceed as follows:
Turn the machine off;
place the switch no. 11 of the SW2 micro-switch
battery in the ON position, as shown in the electrical
diagram on the next page;
connect the supplied CA cable (code 22554011) from
the CN13 dedicated connector of the CE electronic
board (cod.18090099); to the CN3 connector of the
IN interface;
connect the CS serial cable (code 22554010) from the
CN4 dedicated connector of the CE electronic board
to the CN8 connector of the IN interface;
connect the CH hartwall cable (code 22554004)
between the connector of the IN interface and the
cash register;
position the JP1 and JP2 jumpers on the IN interface,
as shown in the following diagram
close the JP5 jumper on the IN interface;
start the machine again.
The management software of the register and
i
the of the hartwall CH at the register, are not the
responsibility of the manufacturer The switch of the
interface can't be in PROG. position