Automatic Heating And Foaming; Automatic Heating; Manual Heating And Foaming; Automatic Autosteamer Nozzle Cleaning - Wega Wegaconcept Use And Maintenance Manual

Table of Contents

Advertisement

!
Before using the steam to heat beverages or to
foam milk, you should first let some steam off until
all the condensation water is
19.2

Automatic heating and foaming

Proceed as follows:
Immerge the tips of the autosteamer
(13) into the beverage;
press the
or
on the dose of milk in the jug;
wait until the delivery is fi nished;
when the delivery is fi nished, the milk
will be foamed and heated at the preset
temperature.
To stop delivery in advance, press the same key again;
to prolong the delivery of steam, use the "Manual
steam" key
.
To increase or decrease the consistency of the foam,
slightly adjust the special regulator (A). Turning it
clockwise will decrease the consistency, while turning
it counter-clockwise will increase it.
Always proceed by performing slight adjustments.
Technical manual
released.
13
key, depending
The autosteamer foaming is factory-adjusted during
!
the testing phase of the machine. Therefore, it is
recommended to modify the adjustment only if
strictly necessary.
19.3

Automatic heating

Proceed as follows:
Immerge the tips of the autosteamer (13) into the
beverage;
press the key
wait until the delivery is fi nished;
once the delivery is fi nished, the milk will be heated
at the programmed temperature, but not foamed.
To stop delivery in advance, press the same key again;
to prolong the delivery of steam, use the "Manual
steam" key
.
19.4

Manual heating and foaming

This control allows the user to use the autosteamer
nozzle manually like a normal steam nozzle.
Proceed as follows:
Immerge the tips of the autosteamer (13) into the
beverage;
press the
key;
To stop delivery, press the same key again.
19.5
Automatic autosteamer nozzle
cleaning.
After 120 minutes of idle time the automatic cleaning
of the nozzle starts, lasting 15 seconds.
The following message will appear on the display:
"STEAM CLEANING CYCLE"
A minimum amount of steam will come out of the
nozzle.
!
The use of the steam delivery point (steam nozzle),
must always be preceded by condensation draining
for at least 2 seconds.
A
Wegaconcept
;
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents