Schedules Maintenance; Alarm Display - Wega Wegaconcept Use And Maintenance Manual

Table of Contents

Advertisement

Wegaconcept
30

Schedules maintenance

30.1

Alarm display

This function permits verification of the last 8 alarms
detected by the machine.
ENTER
Hold down the ENTER button for at least 5 seconds.
(x 5 secs.)
Scroll the menu until the item is highlighted
09 FILTER REGENERAT.
10 COUNTERS
11 CLOCK SETUP
12 WORKING DAYS
ENTER
Confirm to access the menu
TOTAL COFFEES
XXXXXXXX
Press ( ) or ( ) to display the last 8 alarms memo-
rized by the system
XX - DDMMYY
XX - DDMMYY
XX - DDMMYY
XX - DDMMYY
XX
Alarm code.
Last alarm date
DDMMYY
To reset the alarms proceed as follows.
XX - DDMMYY
XX - DDMMYY
XX - DDMMYY
XX - DDMMYY
The alarms can be reset by pressing the button ( ) for
at least 3 seconds.
RESET ALARMS?
PRESS KEY ^ 3 SEC
confirm by pressing ( ) for 3 seconds.
i
The alarm view and reset functions are enabled
ONLY for the technician.
52
XX - DDMMYY
XX - DDMMYY
XX - DDMMYY
XX - DDMMYY
XX - DDMMYY
XX - DDMMYY
XX - DDMMYY
XX - DDMMYY
Alarms code table:
Code Alarm description
1
Heat sensor group open on group 1
2
Heat sensor group open on group 2
3
Heat sensor group open on group 3
4
Heat sensor group open on group 4
5
Check heating circuit group on group 1
6
Check heating circuit group on group 2
7
Check heating circuit group on group 3
8
Check heating circuit group on group 4
9
Water heat sensor open on group 1
10
Water heat sensor open on group 2
11
Water heat sensor open on group 3
12
Water heat sensor open on group 4
13
Check water heat sensor on group 1
14
Check water heat sensor on group 2
15
Check water heat sensor on group 3
16
Check water heat sensor on group 4
17
Steam boiler sensor open
18
Steam boiler heat circuit
19
Cup heater: sensor disconnected
20
Cup heater: sensor short circuit or excessive temperature
21
Autosteamer: sensor disconnected
22
Cup heater: sensor short circuit or excessive temperature
23
Steam boiler heating timeout
24
Heating group timeout on group 1 - Machine start
25
Heating group timeout on group 2 - Machine start
26
Heating group timeout on group 3 - Machine start
27
Heating group timeout on group 4 - Machine start
28
Heating group out of service on group 1 - Machine running
29
Heating group out of service on group 2 - Machine running
30
Heating group out of service on group 3 - Machine running
31
Heating group out of service on group 4 - Machine running
32
Coffee water heater timeout on group 1 - Machine start
33
Coffee water heater timeout on group 2 - Machine start
34
Coffee water heater timeout on group 3 - Machine start
35
Coffee water heater timeout on group 4 - Machine start
36
Coffee water heating coffee water on group 1 - Machine running
37
Coffee water heating coffee water on group 2 - Machine running
38
Coffee water heating coffee water on group 3 - Machine running
39
Coffee water heating coffee water on group 4 - Machine running
40
Filling timeout. First coffee boiler/steam filling 255"
41
Filling timeout. Top off steam boiler level 90"(180"for coffee boiler)
42
Safety level. Steam boiler
43
Coffee water pressure group 1. Pressure timeout.
44
Coffee water pressure group 2. Pressure timeout.
45
Coffee water pressure group 3. Pressure timeout.
46
Coffee water pressure group 4. Pressure timeout.
47
Volumetric dosing device 1
48
Volumetric dosing device 2
49
Volumetric dosing device 3
50
Volumetric dosing device 4
51
Water softener regeneration