Motor Connection - Lenze E931E Series Hardware Manual

Servo inverters for extra-low voltages
Table of Contents

Advertisement

5.4

Motor connection

For trouble−free operation, we recommend to use Lenze standard cables.
ƒ
Ensure a proper shielding of the motor and feedback cable to avoid interferences.
ƒ
X3 motor connection
Pin No.
Designation
1
U
2
V
3
W
4
BR+
5
BR−
Terminal data
Cable
Flexible
With wire end
ferrule
(
Stop!
The brake is supplied by the control voltage at X2. In order to ensure the
trouble−free operation of the brake, the control voltage has to be in the
tolerance range of the brake used!
GHB 13.0001−EN EN 3.0
efesotomasyon.com - Lenze
Specification
Motor phases
Fundamental wave in case of
overload for 2 s up to 32 A
Brake
Max. conductor cross−section
2
[mm
]
[AWG]
2.5
12
l
Electrical installation
Motor connection
approx. 0 V ... 27 V
0 V ... 13 A
eff
eff
0 Hz ... 200 Hz
24V DC
0 V
Tightening torque
[Nm]
[lb−in]
0.5 ... 0.6
4.4 ... 5.3
5
eff
Screw drive
Slot 0.6 x 3.5
25

Advertisement

Table of Contents
loading

Table of Contents