5
Electrical installation
Voltage supply
(
Stop!
The maximum permissible current loading of the terminal strip X2 is 16 A per
terminal. If required, the supply voltage has to be connected in parallel!
X2 supply voltage
Pin No. Designation
1
UL
2
3
BR
4
24 V
5
GND
6
7
Terminal data
Cable
Flexible
With wire end
ferrule
External brake resistors
(
Stop!
The drive controller does not monitor the temperature of the external resistor.
For this purpose, additional safety measures are to be considered!
The drive controller is provided with an integrated brake resistor which is designed for a
permanent power of 10 W or for a pulse power of 200 W for 50 ms.
If higher permanent or pulse powers are required, you can connect an additional external
brake resistor to the integrated brake chopper.
If the switching threshold of the brake chopper is exceeded, both resistors are energised.
Parameter
Switching threshold brake chopper on
Switching threshold brake chopper off
Resistance, external
Rated power
24
efesotomasyon.com - Lenze
Value
Specification
24 ... 48 V
DC−bus voltage output stage
As 1, loop through of the supply to further drives
Connection external brake resistor against UL
+24 V / 1.5 A
Control voltage for control section, DOUT0, DOUT1, DOUT2 and holding
brake, max. 1.5 A
As 4, loop through of the supply to further drives
0 V
Common reference potential for the DC−bus voltage and control voltage
As 6, loop through of the GND potential to further drives
Max. conductor cross−section
2
[mm
]
[AWG]
2.5
12
Value
Approx. 63 V
Approx. 60 V
> 5 W
10 W ... 600 W
l
Tightening torque
[Nm]
[lb−in]
0.5 ... 0.6
4.4 ... 5.3
GHB 13.0001−EN EN 3.0
Screw drive
Slot 0.6 x 3.5