Commissioning
Initial switch−on
Basic settings:
1. Connect the serial interface on the drive controller and on the PC to a null modem
cable.
2. Switch on the control voltage, but not yet the power supply!
– If the green LED (state) is blinking, the voltage is in the permissible range.
3. Start the »Small Drive Control (SDC)« parameterisation software.
– If you are not able to effect a connection between the PC and the drive controller,
check the setting of the serial interface on the PC (see Software Manual).
– If communication is defective, a message is displayed on the user interface.
4. Select the item "Select as commissioned" in the window "Initial commissioning".
– Ignore the error messages which are displayed due to the power supply that is not
yet existent.
5. Select the connected motor in the "Parameters W Drive parameters W Motor data…"
menu.
– If you select a motor from the integrated motor data base, you do not have to
enter the motor parameters manually.
– If you do not find the connected motor in the motor data base, you have to enter
the motor parameters manually. The data can be gathered from the nameplate of
the motor.
6. Select and parameterise the connected encoder system in the "Parameters W Drive
parameters W Resolver settings…" menu.
7. Select the operating mode "Speed control" in the window "Commands".
8. Assign the setpoint sources in the "Operating mode W Setpoint selection..." menu:
– analog speed setpoint (±10 V DC) via AIN0