Omron CK3W-AX1313 Series Startup Manual page 29

Programmable multi-axis controller for directpwm interface
Hide thumbs Also See for CK3W-AX1313 Series:
Table of Contents

Advertisement

No.
Set item
*13
Motor[1].PwmSf
*14
Motor[1].PhaseOff-
set
*15
Motor[1].AmpFault-
Level
*16
Motor[1].WarnFeLi-
mit
*17
Motor[1].FatalFeLi-
mit
*18
Motor[1].Current-
NullPeriod
*19
Motor[1].pEnc
*20
Motor[1].pEnc2
*21
Motor[1].pDac
*22
Motor[1].pAdc
*23
Motor[1].AdcMask
*24
Motor[1].MaxDac
CK3M-series Startup Guide DirectPWM Interface (O047)
Set value
13458
Set a scale factor for PWM output. The full range is 16384.
The scale factor is normally set to less than 95% of the full range so
that PWM waveform cannot reach the duty cycle of 0% or 100%. It is
set to approximately 82% in this example.
Set it depending on the Servo Drive specifications.
683
For a three-phase motor, set to 683 or −683.
1
Specify a logic of AMP Fault detection. Set it depending on the Servo
Drive specifications.
0: Negative logic is used to detect AMP Fault.
1: Positive logic is used to detect AMP Fault.
4000
The status bit Motor[1].AmpWarn is set when the positional deviation
exceeds this value.
The value for a half-rotation of the motor is set in this example. Set it
depending on applications used.
8000
The motor is killed and the status bit Motor[1].FeFatal is set when the
positional deviation exceeds this value.
The value for a half-rotation of the motor is set in this example. Set it
depending on applications used.
1
Motor[1].IaBias and Motor[1].IbBias are set in
Motor[1].PhaseFindingStep=1 during phase search.
EncTable[1].a
Specify the digital quadrature encoder as an address used for loop
feedback to control the motor position.
The digital quadrature encoder is assigned to EncTable[1] in Notes *2
in this example.
EncTable[1].a
Specify the digital quadrature encoder as the address used for loop
feedback to control the motor velocity.
The digital quadrature encoder is assigned to EncTable[1] in Notes *2
in this example.
Gate3[0].Chan[0].P
Assign DirectPWM to the motor command output register.
wm[0].a
Gate3[0].Chan[0].A
Specify the DirectPWM interface AD converter as an AD converter
dcAmp[0].a
used for digital current feedback.
$FFFC0000
Specify which bit of 32 bits current feedback word is used as the actual
current value.
The 14 bits AD converter is set in this example. Set it depending on the
Servo Drive specifications.
28377*3.33/11.25
Set an instantaneous current limit value (root mean square: RMS).
Compare those of the Servo Drive and the motor, and use a smaller
value. The motor has a smaller value in this example.
Use the following formula for calculation.
MaxDac =
Determine parameters depending on the equipment used.
The following shows parameters for equipment used in this example.
Maximum instantaneous current for R88M-K05030T: 4.7 A (p-p)/√2 =
3.33 A (RMS)
ADC full range current for CDHD-0032APB0: 11.25 A (RMS)
3 DirectPWM Interface Connection Procedure
Description
Cos (30°) × 32767 × Maximum instantaneous current
Servo driver ADC full-range current
3
3-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ck3w-ax2323 series

Table of Contents