4.7 Software Signal Pulse and User Output

The software signal pulse block contains eight general purpose registers which allow
generating internal pulse signals by software access. These pulse signals are internally
connected to following functions, where it can be used to start a procedure:
Acquisition Start Trigger
Acquisition End Trigger
Frame Start Trigger
Frame Burst Start Trigger
Frame Burst End Trigger
Exposure Start Trigger
Exposure End Trigger
Counter Trigger
Counter Event
Counter Reset
Timer Trigger
The user output block is an eight bit status register. The bits can be set to 0 or 1 by software.
The bits are available in the following firmware blocks/functions:
Counter Trigger
Counter Reset
LED S0, S1 and S2
Line Out