C.3.4 Missed Trigger Counter
For monitoring purposes it might be necessary to detect an overtriggering condition. It means,
that not all applied triggers can be processed by the camera. This can be done by setting up of
a missed trigger counter. Any of the four available counters can be used as a missed trigger
counter. The following configuration procedure must be applied:
1.
Select one of the four available counters by setting of the CounterSelector to Counter0,
Counter1, Counter2 or Counter3.
2.
Set the corresponding CounterEventSource to MissedAcqStartTrigger,
MissedFrameStartTrigger, MissedFrameBurstStartTrigger, MissedExposureStartTrigger or
MissedTrigger.
3.
Parameter TimerTriggerActivation can be ignored. This configuration is only necessary,
when Line0 input is selected as a trigger source.
4.
All other counter parameter must be left in default state (Both the CounterResetSource and
CounterTriggerSource must be set to Off).
5.
The counter needs to be reset (see C.3.1).