5 Counter & Timer

5.2.4 Timer Reset

The timer can be reset by a software command. It performs a software reset of the timer
counter and starts the timer immediately (change to state timer active), when trigger source is
set to off; otherwise it goes into the state timer trigger wait.

5.2.5 Timer Trigger Source

The timer trigger source selects the events that will be the used to reset and to start the timer.
The following list of signals are available:
Off Disables the timer trigger.
Acquisition Trigger Starts with the reception of the acquisition trigger event.
Acquisition Start Starts with the reception of the acquisition start event.
Acquisition End Starts with the reception of the acquisition end event.
FrameTrigger Starts with the reception of the frame trigger event.
Frame Start Starts with the reception of the frame start event.
Frame End Starts with the reception of the frame end event.
Frame Burst Start Starts with the reception of the frame burst start event.
Frame Burst End Starts with the reception of the frame burst end event.
Exposure Start Starts with the reception of the exposure start event.
Exposure End Starts with the reception of the exposure end event.
User Output 0 ... 7 Starts when the selected user output bit is set to 1.
Counter 0 ... 3 Start Starts with the reception of the chosen counter start event.
Counter 0 ... 3 End Starts with the reception of the chosen counter end event.
Timer 0 ... 3 Start Starts with the reception of the chosen timer start event.
Timer 0 ... 3 End Starts with the reception of the chosen timer end event.
Action 0 ... 3 Starts with the reception of the chosen action signal event.
Software Signal Pulse 0 ... 7 Starts with the reception of chosen software signal pulse event
(see Section 4.7).
Line Input Starts when the specified counter trigger activation condition is met on the chosen
line.
Line input source has additionally a activation configuration, which needs to be set
accordingly. Following configuration values are available:
Rising Edge Timer starts with the rising edge on the selected line input.
Falling Edge Timer starts with the falling edge on the selected line input.
Both Edges Timer starts with any edge on the selected line input.
A self re-trigger timer can be configured, when the trigger source is set to its
own timer end event. The timer needs a software reset in order to start the self
re-trigger mode.