TABLE 4 - ELECTRICAL LUG DATA (CONT'D)
FIELD WIRING LUGS
QTC4 MODEL
INPUT
MODEL COND
EVAP
VOLTS
290
H
E
300
S
C
300
H
C
310
P
E
315
P
E
320
S
E
330
S
C
340
S
E
340
H
E
QUANTECH
TERMINAL
BLOCK
WIRES
INPUT
PER
FREQ
PHASE
RANGE
SINGLE POINT WIRING
200
60
230
60
380
60
3
#2 - 600 kcmil
400
50
3
#2 - 600 kcmil
460
60
3
#2 - 600 kcmil
575
60
3
#2 - 600 kcmil
200
60
230
60
380
60
3
#2 - 600 kcmil
400
50
3
#2 - 600 kcmil
460
60
3
#2 - 600 kcmil
575
60
3
#2 - 600 kcmil
200
60
230
60
380
60
3
#2 - 600 kcmil
400
50
3
#2 - 600 kcmil
460
60
3
#2 - 600 kcmil
575
60
3
#2 - 600 kcmil
200
60
230
60
380
60
3
#2 - 600 kcmil
400
50
3
#2 - 600 kcmil
460
60
3
#2 - 600 kcmil
575
60
3
#2 - 600 kcmil
200
60
230
60
380
60
3
#2 - 600 kcmil
400
50
3
#2 - 600 kcmil
460
60
3
#2 - 600 kcmil
575
60
3
#2 - 600 kcmil
200
60
230
60
380
60
3
#2 - 600 kcmil
400
50
3
#2 - 600 kcmil
460
60
3
#2 - 600 kcmil
575
60
3
#2 - 600 kcmil
200
60
230
60
380
60
3
#2 - 600 kcmil
400
50
3
#2 - 600 kcmil
460
60
3
#2 - 600 kcmil
575
60
3
#2 - 600 kcmil
200
60
230
60
380
60
3
#2 - 600 kcmil
400
50
3
#2 - 600 kcmil
460
60
3
#2 - 600 kcmil
575
60
3
#2 - 600 kcmil
200
60
230
60
380
60
3
#2 - 600 kcmil
400
50
3
#2 - 600 kcmil
460
60
3
#2 - 600 kcmil
575
60
3
#2 - 600 kcmil
STANDARD & ULTRA QUIET CONDENSER FANS
CIRCUIT
BREAKER
LUG
WIRES
LUG
WIRE
PER
WIRE
PHASE
RANGE
4
#4/0 ~ 500 kcmil
4
#4/0 ~ 500 kcmil
3
#3/0 ~ 400 kcmil
3
#3/0 ~ 400 kcmil
4
#4/0 ~ 500 kcmil
4
#4/0 ~ 500 kcmil
3
#3/0 ~ 400 kcmil
3
#3/0 ~ 400 kcmil
4
#4/0 ~ 500 kcmil
4
#4/0 ~ 500 kcmil
3
#3/0 ~ 400 kcmil
3
#3/0 ~ 400 kcmil
4
#4/0 ~ 500 kcmil
4
#4/0 ~ 500 kcmil
3
#3/0 ~ 400 kcmil
3
#3/0 ~ 400 kcmil
4
#4/0 ~ 500 kcmil
4
#4/0 ~ 500 kcmil
3
#3/0 ~ 400 kcmil
3
#3/0 ~ 400 kcmil
4
#4/0 ~ 500 kcmil
4
#4/0 ~ 500 kcmil
3
#3/0 ~ 400 kcmil
3
#3/0 ~ 400 kcmil
4
#4/0 ~ 500 kcmil
4
#4/0 ~ 500 kcmil
3
#3/0 ~ 400 kcmil
3
#3/0 ~ 400 kcmil
4
#4/0 ~ 500 kcmil
4
#4/0 ~ 500 kcmil
3
#3/0 ~ 400 kcmil
3
#3/0 ~ 400 kcmil
4
#4/0 ~ 500 kcmil
4
#4/0 ~ 500 kcmil
3
#3/0 ~ 400 kcmil
3
#3/0 ~ 400 kcmil
SECTION 4 - INSTALLATION
NON-FUSED
DISCONNECT SWITCH
WIRES
LUG
PER
WIRE
PHASE
RANGE
4*
#2 - 600 kcmil
3
#2 ~ 600 kcmil
3
#2 ~ 600 kcmil
3
#2 ~ 600 kcmil
4*
#2 - 600 kcmil
3
#2 ~ 600 kcmil
3
#2 ~ 600 kcmil
3
#2 ~ 600 kcmil
4*
#2 - 600 kcmil
3
#2 ~ 600 kcmil
3
#2 ~ 600 kcmil
3
#2 ~ 600 kcmil
4*
#2 - 600 kcmil
3
#2 ~ 600 kcmil
3
#2 ~ 600 kcmil
3
#2 ~ 600 kcmil
4*
#2 - 600 kcmil
3
#2 ~ 600 kcmil
3
#2 ~ 600 kcmil
3
#2 ~ 600 kcmil
4*
#2 - 600 kcmil
3
#2 ~ 600 kcmil
3
#2 ~ 600 kcmil
3
#2 ~ 600 kcmil
4*
#2 - 600 kcmil
3
#2 ~ 600 kcmil
3
#2 ~ 600 kcmil
3
#2 ~ 600 kcmil
4*
#2 - 600 kcmil
3
#2 ~ 600 kcmil
3
#2 ~ 600 kcmil
3
#2 ~ 600 kcmil
4*
#2 - 600 kcmil
3
#2 ~ 600 kcmil
3
#2 ~ 600 kcmil
3
#2 ~ 600 kcmil