5.5  Configure the Fleet Interface Network Settings
If there are other devices in the network that communicate with the fleet, you require the
l
IP address of the network domain (DSN) server, so that the Enterprise Manager appli-
ance can resolve all IP addresses.
Configure the Management Interface network connections as follows:
1. In the SetNetGo web interface, click the Network Tab.
2. Click Management Interface and enter the:
a. IP address.
b. Subnet mask.
c. Network Gateway IP address (typically a router).
3. Enter the IP address of your Domain Name Server (DNS), if required for devices other
than the appliance and the fleet. Otherwise, leave it as 0.0.0.0.
4. Click Apply.
A message dialog informs you of the status of the change, and whether there is any affect on
operations such as a restart or a time delay before the change takes effect.

5.5 Configure the Fleet Interface Network Settings

To configure the Fleet Interface, you require:
A dedicated static IP address. Do not use 1.2.3.4. That address is permanently assigned
l
to the Maintenance Ethernet port.
The subnet mask for the network that your Fleet will use.
l
The IP address of the network Gateway
l
Configure the Fleet Interface network connections as follows:
1. In the SetNetGo web interface, click the Network Tab.
2. Click Fleet Interface and enter the:
a. IP address.
b. Subnet mask.
c. Network Gateway IP address (typically a router).
3. Click Apply.
A message dialog informs you of the status of the change, and whether there is any affect on
operations such as a restart or a time delay before the change takes effect.