6.3

Parameter description

176.1
Mode
Activation of the analog input and output channels:
12 ... 31 Reserved
Bit
Meaning
0
1: Switch on channel analog input 1
0: Switch off channel analog input 1
1
1: Switch on channel analog input 2
0: Switch off channel analog input 2
2
1: Switch on channel analog input 3
0: Switch off channel analog input 3
3
1: Switch on channel analog input 4
0: Switch off channel analog input 4
4 ... 7
Reserved
8
1: Switch on channel analog output 1
0: Switch off channel analog output 1
9
1: Switch on channel analog output 2
0: Switch off channel analog output 2
10
1: Switch on channel analog output 3
0: Switch off channel analog output 3
11
1: Switch on channel analog output 4
0: Switch off channel analog output 4
Application handbook Servo pump function V1 for BM5000
DWORD
Document No.: 5.17002.02
Parameters
0x00000000 to 0xFFFFFFFF
6
55