2.10

Switching pressure sensors

2.10 Switching pressure sensors
The servo pump software of the BM5000 has the functionality to switch between two pres-
sure sensors for pressure control. 
If the used sensors have different pressure ranges, also scaling parameters must be
adapted (dataset switch recommended).
Bit 7 in Control word 1 (ZP177.3–)
m False:
m True:
The default used pressure sensor has to be connected to analog input 4 of add-on mod-
ule SVP or analog input 2 of standard module X6.
A second pressure sensor has to be connected at analog input 3 of add-on module SVP
or analog input 1 of standard module X6.

2.11 Maximum positive speed

If the value is set to 0 rpm, the pump only rotates in an anticlockwise direction.
For quicker depressurization it may be necessary for the pump to rotate briefly in the other
(clockwise) direction.
The maximum permissible (clockwise) speed must be calculated based on the pump
manufacturer's documentation.
18
Application handbook Servo pump function V1 for BM5000
Document No.: 5.17002.02
of 76
Pressure control using sensor 2
Pressure control using sensor 1