Connection Pressure Sensor With Current Interface; Typical Connection Pressure Sensor With Current Interface - Baumuller b maXX 5000 Application Handbook

Servo pump function
Hide thumbs Also See for b maXX 5000:
Table of Contents

Advertisement

3.3
Add-on module SVP
All analog IOs must be released via parameter ZP177.2–. In Parameter
oversampling can be set and furthermore the range of current signal 
(0 - 20 mA or 4 - 20 mA) can be selected.
In the following table is defined which add-on module is required regarding set and actual
value signal form.
Set values pressure and volume
Field bus
Voltage
0 – 10 V
0/4 - 20 mA
x
x
x
x
x
3.3.1

Connection pressure sensor with current interface

Connection example for a pressure sensor with current output (2-wire version):
Figure 23:
The 24 V supply of pressure sensor is directly supplied by the add-on module SVP.
28
Application handbook Servo pump function V1 for BM5000
Document No.: 5.17002.02
of 76
Pressure actual value
Current
Voltage
Current 0/4 -
0 – 10 V
20 mA
x
x
x
x
Supply 24 V

Typical connection pressure sensor with current interface

Required add-on
module SVP
-
SVP-001-001
x
SVP-001-002/3
SVP-001-001
x
SVP-001-002
x
SVP-001-003
Pressure sensor
Pressure Transmitter
ZP177.3–
Resolution
Dataset setting
pressure
actual value
12 Bit
Field bus with standard
module X6
14 Bit
Field bus with add-on
module SVP
14 Bit
Field bus with add-on
module SVP
14 Bit
Analog
14 Bit
Analog
14 Bit
Analog
Output 0/4..20mA
Baumüller Nürnberg GmbH
an

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents