Pin assignment
Figure 17:
Depending on the used add-on module SVP the following signal forms are required:
m Volume set value interface (Analog input 1 of add-on module SVP):
SVP-001-001/2
Voltage input (0 - 10 V)
SVP-001-003
Current input (0/4 - 20 mA)
m Pressure set value interface (Analog input 2 of add-on module SVP):
SVP-001-001/2
Voltage input (0 - 10 V)
SVP-001-003
Current input (0/4 - 20 mA)
m Pressure actual value interface (Analog input 3 or 4 of add-on module SVP):
SVP-001-001
Voltage input (0 - 10 V)
SVP-001-002/3
Current input (0/4 - 20 mA)
required.
NOTE!
Add-on module SVP-001-00X requires an own 24 V-supply.

Pin assignment SVP-001-00X as analog interface

Volume set value from 0 - 10 V is required.
Volume set value from 0/4 - 20 mA is required.
Pressure set value from 0 - 10 V required.
Pressure set value from 0/4 - 20 mA required.
Pressure sensor with voltage output (0 - 10 V) is required.
Pressure sensor with current output (0/4 - 20 mA) is
Application handbook Servo pump function V1 for BM5000