2.4
Scaling and ramps of volume set values
2.4
Scaling and ramps of volume set values
This scaling defines the scaling-relationship between the voltage-value of the Q-Set fil-
tered (ZP177.35–) in respect to the output drive-speed (nSet). The nSet-value is then
sent to the ramp function generator (see
Figure 9:
2.5
Ramps pressure set values
The Ramp function generator (RFG) generates a function with rising and falling ramps.
The ramp up time can be defined in
pressure value to the pressure maximum value (ZP177.6–). The ramp down time can be
defined in
0 %.
Figure 10:
14
Application handbook Servo pump function V1 for BM5000
Document No.: 5.17002.02
of 76
Scaling and ramps of volume set values
ZP177.207–
and defines the time for the pressure falling down from 100 % to
Pmax = P177.6 =100%
Pressure set value
Analog or field bus
Pressure ramp-up and ramp-down time
ZRamps pressure set values–
ZP177.206–
and sets the time needed to raise the
Pressure ramp function generator
ms
P177.206
Ramp up time
Ramp down time
Pressure set value
Pressure set value
on page 14).
Pressure set value
P177.120
ms
P177.207
Baumüller Nürnberg GmbH