5. Commissioning
Configuration (= equipment on valve termi-
nal/valve sensor terminal)
Enter:
for each group of 8 inputs: 8DI
for each group of 8 outputs: 8DO
The entry fields must be assigned in
ascending order without gaps; no field may
be unused. Always enter inputs before out-
puts.
Example 1:
Valve sensor terminal with
10 valve locations.
Configuration:
8DI, 8DI, 8DI, 8DO, 8DO, 8DO
The 2 status bits increase the number of
inputs to 24 in this case (22I + 2 status bits).
Example 2:
Valve terminal with 10 valve locations.
Configuration:
8DO, 8DO, 8DO