Festo VIFB13-02 Series Manual page 123

Valve terminal/valve sensor terminal with field bus connection, field bus protocol: profibus dp 12 mbaud
Table of Contents

Advertisement

VIFB13 - 02
9701 NH
5. Commissioning
FREEZE
With this function all the inputs of the valve ter-
minal can be "frozen". The valve terminal then
sends a constant input image of all the inputs to
the master. The following FREEZE command
causes the input image to be updated. The up-
dated input image is then sent constantly to the
master.
You can return to normal mode with the com-
mand UNFREEZE.
SYNC
With this function all the outputs of the valve ter-
minal can be "frozen". As a result the valve ter-
minal no longer reacts to modifications to the
output image in the master. The following SYNC
command causes the output image of the master
to be updated and transferred.
You can return to normal mode with the com-
mand UNSYNC.
5-45