6.5 Fail-Safe
Fail-Safe – Turns the Fail Safe function
on or off. If the function is disabled, no
pulses on the receiver outputs are
generated in case of signal loss. If this
function is enabled, the receiver
outputs can be configured individually
with the following options:
Hold - The receiver repeats the last known values on its output.
Out OFF - the output pin is deactivated.
Fail-Safe - the output is moved to a position given by the
parameter "Value" at a speed given by "Speed" parameter. You
can set the Fail-Safe positions either by editing each output
value separately or by simply moving the transmitter controls to
the required position and activating the "Set fail-safe position
now" command.
Fail-Safe Delay – Indicates the time interval from a moment the
receiver detects signal loss to when the fail-safe control throws are
initiated. After the expiration of this time, the receiver outputs will
transfer to preset defaults or will be turned off (according to
individual pin settings).