Siemens SIRIUS 3RW5 Manual page 96

Soft starters and solid-state switching devices, ethernet/ip communication module
Hide thumbs Also See for SIRIUS 3RW5:
Table of Contents

Advertisement

Appendix
A.9 Dataset Object
Object
Byte
Bit Data
No.
format
2326
321
0
Bit4
2327
323
0
UINT
2329
325
0
USINT Alternative stopping torque
2332
327
0
USINT Alternative dynamic braking
2331
329
0
USINT Alternative DC braking torque
6
331
0
Bit4
2211
333
0
UINT
2210
335
0
USINT Motor heating warning limit
5
337
0
Bit2
7
339
0
USINT Recovery time
9
341
0
Bit4
10
343
0
Bit2
96
Parameters
Alternative stopping mode
Alternative stopping time
torque
Tripping class
Remaining time for tripping
warning limit
Response to overload thermal
motor model
Temperature sensor
Response to overload
temperature sensor
Range of values
[encoding]
[0 ... 6]
[0] Coasting down
[1] Voltage ramp
[2] Torque control
[3] Pump stopping mode
[4] DC braking
[5] Dynamic DC braking
[6] Reversing DC braking
4)
0 ... 360 s
[0 ... 3 600]
10 ... 100 %
[2 ... 20]
20 ... 100 %
[4 ... 20]
20 ... 100 %
[4 ... 20]
[0 ... 15]
[0] CLASS 10E
[1] CLASS 20E
[2] CLASS 30E
[3] CLASS 10A
[15] CLASS OFF
0 ... 500 s
[0 ... 500]
0 ... 99 %
[0 ... 99]
[0 ... 1]
[0] Turn off without restart
[1] Turn off with restart
60 ... 1 800 s
[2 ... 60]
[0 ... 2]
[0] Deactivated
[1] Thermoclick
[2] PTC type A
[0 ... 2]
[0] Turn off without restart
[1] Turn off with restart
[2] Warn
SIRIUS 3RW5 EtherNet/IP communication module
Manual, 05/2019, A5E45131885002A/RS-AA/001
Incre-
3RW55
1)
ment
[D
]
2)
-
r/w
3)
[0]
0.1 s
r/w
[100]
5 %
r/w
[2]
5 %
r/w
[10]
5 %
r/w
[10]
-
r/w
3)
[0]
1 s
r/w
[0]
1 %
r/w
[0]
-
r/w
3)
[0]
30 s
r/w
3)
[10]
-
r/w
3)
[0]
-
r/w
3)
[0]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents