Instance 100 (0x64): Process image output (PIQ)
Read access (get, r) and write access (set, w) to the process image output (PIQ) are
possible.
Byte
Bit
Data format
0
0
BOOL
1
BOOL
3
BOOL
4
BOOL
5
BOOL
6
BOOL
1
0
BOOL
1
BOOL
2
BOOL
3
BOOL
7
BOOL
2
0
BOOL
3
BOOL
3
0
BOOL
1
BOOL
2
BOOL
Supported by SIRIUS 3RW52 soft starter
1)
Supported by SIRIUS 3RW55 soft starter
2)
Control data is relevant for EX applications
3)
You can assign the control data "Output 1", "Output 2" and "Output 3" to the digital outputs 1, 2 and 4 of the
4)
3RW55 soft starter in any order via the digital output actions. You will find more information in the Equipment Manual of
the 3RW5 soft starter.
Explanation in the following table
5)
More information
The following table describes the assignment of the process images "Parameter set bit 0"
and "Parameter set bit 1":
Parameter set
Process image error
Parameter set 1 (PS1)
Parameter set 2 (PS2)
Parameter set 3 (PS3)
SIRIUS 3RW5 EtherNet/IP communication module
Manual, 05/2019, A5E45131885002A/RS-AA/001
Process image
Motor CW
Motor CCW
Reset
Emergency start
Self-test (user-test)
Creep speed
Output 1
4)
Output 2
4)
Parameter set bit 0
5)
Parameter set bit 1
5)
Disable quick-stop
Output 3
4)
Pump cleaning
Manual operation local - input controlled
Use alternative stopping mode
Motor standstill
Parameter set bit 0
1
0
1
0
Appendix
A.7 Assembly Object
3RW
52
1)
r/w
-
r/w
-
r/w
-
-
-
-
-
-
-
-
r/w
-
-
Parameter set bit 1
1
0
0
1
55
2)
r/w
r/w
r/w
r/w
3)
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
79