6. OPERATION

6.1 Configuration on PM200
You could configure the battery type and capacity through PM235 master power unit.

6.1.1 Battery Capacity and Battery Type

There is a dip switch for you to set battery capacity and battery type.
1 2 3 4
Figure 23 Dip Switch of PM200
Configure the max charging current of PM235:
DS1
DS2
BATTERY
CAPACITY
ON
ON
50Ah
ON
OFF
100Ah
OFF
ON
150Ah
OFF
OFF
200Ah
Table 13 Battery Capacity setting by dip switch
Configure the battery type connected:
DS3
DS4
BATTERY
ABSORPTION FLOAT
TYPE
OFF
OFF
AGM
14.4V
OFF
ON
GEL
14.1V
ON
OFF
LiFePO
14.4V
4
ON
ON
WET
14.7V
Table 14 Battery Type setting by dip switch
16
Dip switch definitions:
ON
DIP
SWITCH
OFF
Table 12 Dip Switch definition
CHARGING
CURRENT OF
PM235
5A
10A
15A
20A
13.5V
13.5V
13.5V
13.7V
1
2
Battery Capacity
When choosing max charging current, please take
into consideration the consumption of the DC load
connected with the system.
Factory default setting:
DIP SWITCH
1
STATUS
OFF
Table 15 Factory default setting
3
4
Battery Type
2
3
4
OFF
OFF
OFF