7. TROUBLE SHOOTING

7.1 L.E.D Display on PM235 Unit
No.
LED
COLOUR
1
Mains
2
Str Bat
3
PV
4
Fuse L.E.D
5
FAULT
Table 17 Error LED indicator of PM235
18
STATUS
Quick flashing
GREEN
(flash twice every second)
Quick flashing
GREEN
(flash twice every second)
Quick flashing
GREEN
(flash twice every second)
Red
OFF
ON
1 flash
2 flash
RED
3 flash
4 flash
5 flash
6 flash
DESCRIPTION
AC input abnormal
The Starter Battery is 2~13.4V or >16.0V, while
AC power is connected.
Solar input voltage error – Solar input >25Vdc
Fuse blown, need to check load and replace fuse
Short circuit
Service battery voltage low
Service battery voltage height
Over temp (heat sink)
Bulk charge timeout
VCR anomaly
Over temp (environment)