4.3 Preparation
PM200 system is designed with a concept of 'Plug and Play' in mind. To complete the easy installation, a screw driver and DC cables are
required. Follow Table 7 recommendation for minimum wiring.
CURRENT
MINIMUM CABLE SIZE
0–5A
1.0mm
or 18 AWG
2
5–10A
2.0mm
or 14 AWG
2
10–15A
3.0mm
or 13 AWG
2
15–20A
4.0mm
or 11 AWG
2
20–25A
5.0mm
or 10 AWG
2
25–30A
6.0mm
or 9 AWG
2
Table 7 Minimum cable size
4.4 Connection
PM200 unit is designed with a spring and screw terminal. Please refer to following illustration at right.
Each type of terminal is designed to fit a different range of cables.
TYPE
TERMINAL MODEL
NUMBER
Type 1
ERTB10-10.16
Type 2
wago804-114
Table 8 Recommended terminal and cable gauge
TYPE 1
Figure 19 Connection of Terminal Type 1
TYPE 2
Figure 20 Connection of Terminal Type 2
When running cables, if they pass through panels or wall, ensure the
cables are protected from damage by sharp edges. In such cases, it is
recommended to use cable glands.
SUITABLE CABLE GAUGE
0.5mm
2
– 10mm
2
0.25mm
2
– 2.5mm
2
Figure 18 PM235 Terminal
Type 1
Type 2
13