Commands
6.2.3.8
Command
getranges b
# = channel number
1 ... 5 b or
# = 1 ... 495
6.2.3.9
Command
getusertime b
Board = colorCONTROL MFA-5
Channel = checkpoint
colorCONTROL MFA-5

Read Ranges of the Intensities for all Optical Fibers

getranges b
Description
Read ranges of the in-
tensities of a colorCON-
TROL MFA-5 system for
all channels

Read User-defined Test Time

getusertime b
Description
Read user-defined test
time
Received
Example
m-f m-f m-f
getranges 2
m-f m-f
Output format
2-0 2-0 3-1 1-0 6-1
Received
Example
xxxxx
getusertime
(of board 1)
Output format
01000
Note
Chapter
6.2.2.2
m = test time (0-8)
f = sensor area (0/1)
0 = 3x3, 1 =9x9
b = board
Note
Time in ms, b =
board.
If specified, otherwise
board 1