17. Technical data

Optical
Detection area length
Max. detection area at 2.1 m (82.7 in)
Min. object detection at 2.1 m (82.7 in)
Aperture angle
Wavelength IR
Mechanical
Dimensions (w × h × d)
Housing material
Enclosure rating
Temperature range
Electrical
Supply voltage U
SP
Max. Ripple at U
SP
Current consumption at 24 VDC
Output
Max. output load
Response time (typical)
Output status indication LED
Connection cable and electrical connection
Material
Diameter
Cable length
Connection
Wires
• brown
• blue
• black
• white
• gray
• green
General
Eye safety norm
EMC emission
EMC immunity
Vibration
Shock
Safety devices for power operated doors and gates
Cable durability
RoHS
Certificates
16
0 ... 3 m (10 ft)
1,470 mm × 400 mm (65.3 in × 15.7 in)
100 mm (3.9 in)
43°
850 nm
139 × 69 × 59 mm (5.5 × 2.8 × 2.4 in)
Polycarbonate (PC)
IP50
−20 °C ... +45 °C (−4 °F... +113 °F)
24 VDC ±10 %
10 %
Ø 150 mA (peak max. 400 mA)
PNP or NPN
50 mA, 100 nF
150 ms
Red = object detected
Green = no object
PVC, black
Ø 4.8 mm (3/16 in)
3 m (9.84 ft)
M8, 6-pin
AWG26
U
(24 VDC ±10 %)
SP
GND (0 V)
PNP or NPN
Test input
Synchronization
Synchronization
EN 62471
EN 61000-6-3
EN 61000-6-2
EN 60068-2-6
EN 60068-2-27
EN 13849-1, Cat. 2, PL C
IEC 60227-2
2011/65/EU
CE, SGS TÜV
© CEDES | V 1.3