Technical Data - Cedes TLS 600 Installation And Operation Manual

Hide thumbs Also See for TLS 600:
Table of Contents

Advertisement

TLS 600

16. Technical data

Optical
Max. operating range (on Kodak white)
Detection area at 2 m (6.5 ft) distance
Min. distance to background
Adjustable recalibration time
Max. ambient light
Mechanical
Dimensions (w × h × d)
Housing material
Housing color
Enclosure rating
Temperature range
Mounting bracket - angle adjustment
Electrical
Supply voltage U
SP
Max. current consumption at 24 VDC
Output
Max. response time
Connection cable and electrical connection
Length
Diameter
Material
Wires
• brown
• blue
• black
• white
General
EMC emission
EMC immunity
Shock
Vibration
RoHS
Certificate
© CEDES | V 1.0
4 m (13 ft)
860 mm × 280 mm (34 in × 11 in)
0.2 m (7.9 in)
3 ... 180 s
100,000 Lux
62 × 18 × 32 mm (2.4 × 0.7 × 1.3 in)
Polycarbonate, ABS
Black
IP40
−20 °C ... +60 °C (−4 °F ... +140 °F)
0° ... 20°
10 ... 30 VDC
40 mA
PNP or NPN
150 ms
2 m
Ø 3.4 mm (0.13 in)
PVC, black
AWG26
U
(10 ... 30 VDC)
SP
GND (0 V)
Output
Test input
EN 61000-6-3:2007
EN 61000-6-2:2005
EN 60068-2-27:2009
EN 60068-2-6:2008
2011/65/EU
CE
English