6. Configuration

There are four DIP switches and two potentiometers
to adjust the TOF/Taxi according to the application.
Use a small screw driver and carefully adjust the
settings.
NOTICE
Mechanical damage to the TOF/Taxi
Do not turn the potentiometers beyond
their mechanical limits.
6.1 DIP switch 1 – Mounting position
The TOF/Taxi can be mounted on the right or left
side of a door, facing downward. The left or right
mounting position is set using DIP switch 1.
Important: Whether the mounting position is above
the leading or the hinge edge of the door is irrelevant
to the setting of DIP switch 1.
DIP switch 1 position
ON
OFF
Table 1: DIP switch 1 settings
6.2 DIP switch 2 – Number of active rows
The detection area of the TOF/Taxi consists of
three rows of IR beams ( Figure 8 for details).
DIP switch 2 activates either only the row nearest to
the door (Row 1) or all 3 rows.
DIP switch 2 position
ON
OFF
Table 2: DIP switch 2 settings
© CEDES | V 1.3
Mounting position
Mounting on the right
Mounting on the left
Number of active rows
All 3 rows
Row 1 only
DIP switch
ON
OFF
1
2
3
4
Figure 9: DIP switches and potentiometers on TOF/Taxi
Figure 10: Mounting position on the left and right side of a
swing door
Figure 11: TOF/Taxi with one active row (left) and three active
rows (right). Single rows are shown for clarity.
English
Pot 1
Pot 2
2
2
3
1
1
4
0
0
3
4
7