5. For AC systems, ensure AC supply power is off.
6. For AC systems: turn breaker in cabinet off. Install supply ground into bus bar terminal shown, torque to 20 in-
lb. Install supply line and neutral wires into AC Input terminals, torque to 6 in-lb. Secure cable jacket to
chassis with cable tie.
ELECTRICAL SHOCK HAZARD. DO NOT ENERGIZE AC SUPPLY OR TURN CABINET
BREAKER(S) ON UNTIL ALL SYSTEM WIRING IS COMPLETED.
The ground bus bar accepts 4-14AWG copper wire.
The DIN rail terminal blocks accept 10 – 26AWG copper wire.
7. Proceed with installation of other system elements described in
Carmanah Technologies Corp. | 250 Bay St, Victoria, BC V9A 3K5, Canada | 1.250.380.0052 |
G SERIES USER MANUAL
3.0 SOLAR PANEL AND CABINET INSTALLATION
Section 4
and
Section
customerservice@carmanah.com
5.
34
|
carmanahtraffic.com