Emerson FB1100 Quick Start Manual page 9

Flow computer
Table of Contents

Advertisement

Use the following bolt installation procedure:
1.
Carbon steel bolts do not require lubrication. Stainless steel bolts are factory-coated with a
lubricant to ease installation. Do not apply any additional lubricant when installing either
type of bolt.
2.
Finger-tighten the bolts.
3.
Torque the bolts to the initial torque value using a crossing pattern. See
initial torque value.
4.
Torque the bolts to the final torque value using the same crossing pattern. See
final torque value.
5.
Verify that the flange bolts protrude through the sensor module before applying
pressure.
Table 2: Torque Values for the Flange and Flange Adapter Bolts
Bolt
material
Carbon
Steel (CS)
Stainless
Steel (SST)
Proper Bolt Installation
1
Bolt
2
Sensor module
Emerson FB1100 Flow Computer Quick Start Guide
Head markings
D301785X012
March 2019
Table 2
for
Table 2
Initial torque
Final torque
300 in. -lbs.
650 in. -lbs.
(33.9 N m)
(73.4 N m)
150 in. -lbs.
300 in. -lbs.
(16.9 N m)
(33.9 N m)
for
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents