Inline Mounting Kit

DANGER
EXPLOSION HAZARD: Ensure the area in which you perform this operation is non-hazardous.
Performing this operation in a hazardous area could result in an explosion.
1
Pipe mounting bracket
2
U-bolt 2 ½ inch diam. pipe (5/16-18 x 3.75 long)
3
5/16 flat lock washer (2)
4
5/16-18 300 series hex nut (2) - Apply Loctite 222 Low Strength Purple Threadlocker to threads. Torque
nuts to 30 in-lbs (3.4 N m)
5
U-bolt clamp assembly - Apply Loctite 222 threadlocker to threads. Torque nuts to 30 in-lbs (3.4 N m)