 1 The limits of use of S800 ENC in relation to the wind
The table shows the maximum wind allowed for S800 ENC based on the leaf surface exposed to the wind.
Winds that exceed those allowed may affect the integrity of the mechanical transmission components of S800 ENC.
It is the responsibility of the installer to assess the impact of the wind on all the elements of the structure (columns, hinges, leaves) in order
to define the maximum wind allowed for the automation.
Leaf length (m)
Exposed area (m²)
1
1
12
2
3
10
4
5
6
9
7
8
9
8
10
11
12
13
7
14
15
16
Strength and name of the wind
(Beaufort scale)
0
Calm
1
Light air
2
Light breeze
3
Gentle breeze
4
Moderate breeze
5
Fresh breeze
6
Strong breeze
7
Near gale
8
Gale
9
Severe gale
10
Storm
11
Violent storm
12
Hurricane
 2 Limits of use of the positive stops
The limits of use of the positive stops in relation to the length and weight of the leaf are indicated in the table below.
Using positive stops beyond the allowed limits is not advisable.
If using the integrated mechanical stops beyond the admissible limits is unavoidable, the minimum positive stop speed must be obtained
by setting at least 30° at slowdown speed.
Leaf length (m)
Leaf weight (kg)
1
50
100
150
200
250
300
350
400
450
500
550
600
650
700
750
800
 = Use of positive stops ALLOWED
 = Use of positive stops NOT RECOMMENDED
S800 ENC
1.25
1.5
1.75
2
11
6
5
Wind speed (km/h)
≤ 1
> 1...6
> 6...11
> 11...19
> 19...29
> 29...39
> 39...50
> 50...62
> 62...75
> 75...87
> 87...102
> 102...117
> 117
1.25
1.5
1.75
2
2.25
2.5
2.75
3
11
10
9
4
2.25
2.5
2.75
3
18
3.25
3.5
3.75
4
3.25
3.5
3.75
4