3. Enter ntutil. The following main menu appears on the screen.
1: Manual Test
2: Batch Test
9: Exit ntutil
Enter selection:
4. Enter 1 in the Enter selection: input area to select Manual Test.
The menu in Figure 74 on page 224 appears.
5. Enter 20 (open) in the Enter selection: input area to open the device.
SYNTAX: open device-file RW
$D
where RW means read/write
RO means read only
for example,
open RW
open $D RO
open tape0 RO
If the special file $D is specified, the -d value must be given on the
command line, and will be substituted for $D.
6. Select by its number the test you want to run. Run the appropriate tests and complete the necessary
tasks, then return here to finish the call.
7. After the tests are complete, enter 21 in the Enter selection: input area to select Close, then press
Enter.
8. Enter 99 to return to the main menu shown in Step 3.
9. Enter 9 to exit ntutil.
10. Return to the procedure that sent you here.
RO
means open default device tape0
means open device specified by -d option
means open device tape0