1 (all other parts of the equipment). The model code and datasheet
are to be consulted for details of the diaphragm material. Installation,
maintenance and use shall take into account the environmental
conditions to which the diaphragm will be subjected. The
manufacturer's instructions for installation and maintenance shall be
followed in detail to assure safety during its expected lifetime.
2. Flameproof joints are not intended for repair.
3. Non-standard paint options may cause risk from electrostatic
discharge. Avoid installations that could cause electrostatic build-up
on painted surfaces, and only clean the painted surfaces with a damp
cloth. If paint is ordered through a special option code, contact the
manufacturer for more information.
China
E3 China Flameproof
Certificate
Standards
Markings
Special Conditions for Safe Use (X):
1. Ambient temperature range: –20 °C
2. The earth connection facility in the enclosure should be connected
reliably.
3. During installation, there should be no mixture harmful to housing.
4. During installation in hazardous location, Cable glands and blanking
plugs, certified by state-appointed inspection bodies with Ex d IIC Gb
type of protection should be used. Redundant cable entries should be
blocked with blanking plugs.
5. During installation, use and maintenance of the product in explosive
gas atmosphere, observe the warning "Don't open the cover when the
circuit is alive".
6. End users is not permitted to change any components insides, but to
settle the problem in conjunction with manufacturer to avoid damage
to the product.
7. When installation, use and maintenance of this product, observe
following standards: GB3836.13-2013 "Explosive atmospheres-Part
13: Equipment repair, overhaul and reclamation" GB3836.15-2000
"Electrical apparatus for explosive gas atmospheres Part 15: Electrical
installations in hazardous area (other than mines)" GB3836.16-2006
"Electrical apparatus for explosive gas atmospheres Part 16: Inspection
32
GYJ15.1300X
GB3836.1-2010, GB3836.2-2010
Ex d IIB+H
T5 Gb