3. Some variants of the equipment have reduced markings on the
nameplate. Refer to the Certificate for full equipment marking.
I1 ATEX Intrinsic Safety and Dust
Certificate Certificate: Baseefa12ATEX0189X; Baseefa12ATEX0191
Standards EN60079-0:2012+A11:2013, EN60079-11:2012,
Markings
Table 4-2: Input Parameters
Parameters
Voltage U
i
Current I
i
Power P
i
Capacitance C
Inductance L
Special Conditions for Safe Use (X):
1. The equipment is not capable of withstanding the 500 V insulation test
required by clause 6.3.13 of EN60079-11:2012. This must be taken
into account when installing the equipment.
2. The enclosure may be made of aluminum alloy and given a protective
polyurethane paint finish; however, care should be taken to protect it
from impact or abrasion if located in Zone 0.
3. Some variants of the equipment have reduced markings on the
nameplate. Refer to the Certificate for full equipment marking.
N1 ATEX Type n and Dust
Certificate Certificate: Baseefa12ATEX0190X; Baseefa12ATEX0191
Standards EN60079-0:2012+A11:2013, EN60079-15:2010,
Markings
II 1 D Ex ta IIIC T95 °C T
Special Conditions for Safe Use (X):
22
EN60079-31:2009
II 1 G Ex ia IIC T5/T4 Ga, T5(–60 °C ≤ T
≤ T
≤ +70 °C)
a
T
≤ +85 °C)
a
HART
30 V
200 mA
0.9 W
0.012 µF
i
0 mH
i
EN60079-31:2009
II 3 G Ex nA IIC T5 Gc (–40 °C ≤ T
105 °C Da (–20 °C ≤ T
500
II 1 D Ex ta IIIC T95 °C T
February 2019
≤ +40 °C), T4(–60 °C
a
10°C Da (–20 °C ≤
500
≤ +70 °C),
a
≤ +85 °C)
a
Emerson.com/Rosemount