Table 8. LCD Message Troubleshooting Table (continued)
PAP UNEXP INT*
32 PAPER JAM
TIMEOUT
31 PAPER OUT
TIMEOUT
PARAMETER
ERROR*
PARITY ERROR
POWER SUPPLY
HOT
PROTECTED
INSTR*
Mantenimiento Periféricos Informáticos SL C/Canteras, 15 28860 Paracuellos de Jarama Tel: 00 34 917481604 WEB: https://mpi.com.es
No
Fatal firmware error
on controller board.
Yes
A timeout message
is sent to the host if
no paper motion
has occurred for 10
minutes after
CLEAR was
pressed to clear the
jam fault.
Yes
A timeout message
is sent to the host if
paper is not loaded
10 minutes after
CLEAR was
pressed to clear the
paper out fault.
No
Illegal parameter
value received in
command code.
Yes
Parity error
(serial interface)
Yes
Power supply
sensors report high
temperatures.
No
Fatal firmware error
on controller board.
Fault Messages
Contact your authorized
1
service representative.
Clear paper jam and
reload paper.
Load paper.
Contact your system
administrator.
Check your serial host
interface parameter
settings; if necessary,
adjust them so that they
match the settings of the
attached host.
Check printer
environment. If hot or
dusty, relocate printer.
Contact your authorized
service representative if
1
this occurs frequently.
Contact your authorized
1
service representative.
235