6. DMX512 Connections

The DMX512 is widely used in intelligent lighting control, with a maximum of 512 channels.
1. Connect the unit together in a "daisy chain" by XLR plug cable from the output of the unit
to the input of the next unit. The cable cannot be branched or split to a "Y" cable.
Inadequate or damaged cables, soldered joints or corroded connectors can easily distort
the signal and shut down the system
2. The DMX output and input connectors are pass-through to maintain the DMX circuit when
no power is connected to the fixture.
3. At last fixture, the DMX cable has to be terminated with a terminator to reduce signal
errors. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a
3-pin XLR-plug and plug it in the DMX-output of the last fixture.
4. Each lighting unit needs to have an address set to receive the data sent by the controller.
The address number is between 0-511 (usually 0 & 1 are equal to 1).
5. 3 pin XLR connectors are more popular than 5 pins XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
8B

7. Fixture Cleaning

The cleaning of internal must be carried out periodically to optimize light output. Cleaning
frequency depends on the environment in which the fixture operates: damp, smoky or
particularly dirty surrounding can cause greater accumulation of dirt on the fixture's optics.
y
Clean with soft cloth using normal glass cleaning fluid.
y
Always dry the parts carefully.
y
Clean the external optics at least every 20 days. Clean the internal optics at least every
30/60 days.