Siemens SINAMICS S120 Equipment Manual page 193

Chassis liquid cooled power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Table 6- 16
1)
Table 6- 17
1)
Chassis Liquid Cooled Power Units
Manual, (GH7), 01/2011, 6SL3097-4AM00-0BP1
Dimensions of dv/dt reactor, 380 V - 480 V 3 AC (all values in mm)
6SL3000-
2DE32-6CA0
a2
25
a3
5
a4
14
a5
10.5 x 14
a6
7
a7
a8
I4
410
I5
135
hmax
370
h2
258
h3
76
n1
141
1)
n2
316
1)
n3
229
n4
72
d3
M10 (12 x 18)
Lengths n1 and n2 correspond to the distance between holes
Dimensions of dv/dt reactor, 500 V - 690 V, Part 1 (all values in mm)
6SL3000-
2DH31-0CA0
a2
25
a3
6
a4
14
a5
10.5 x 14
a6
7
a7
a8
I4
350
I5
120
hmax
320
h2
215
h3
70
n1
138
1)
n2
264
1)
n3
227
n4
74
d3
M8
Lengths n1 and n2 correspond to the distance between holes
2DE35-0CA0
30
6
17
14 x 18
9
-
-
-
-
460
152.5
370
240
83
182
356
275
71
M12 (15 x 22)
2DH31-5CA0
25
6
14
10.5 x 14
7
-
-
-
-
350
120
320
215
70
138
264
227
74
M8
Motor-side power components
6.3 dv/dt filter plus Voltage Peak Limiter
2DE38-4CA0
40
8
22
14 x 18
11
-
-
460
152.5
385
280
78
212
356
312
78
M12 (15 x 22)
2DH32-2CA0
25
5
14
10.5 x 14
7
-
-
460
152.5
360
240
86
155
356
275
101
M12 (15 x 22)
2DE41-4CA0
60
10
19
14 x 18
11
17
26
445
145
385
250
121
212
341
312
78
M12 (15 x 22)
2DH33-3CA0
25
5
14
10.5 x 14
9
-
-
460
152.5
360
240
86
212
356
275
42
M12 (15 x 22)
191

Advertisement

Table of Contents
loading

Table of Contents