Technical Specifications - Siemens SINAMICS S120 Equipment Manual

Chassis liquid cooled power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor-side power components
6.2 Motor reactors
6.2.4

Technical specifications

Table 6- 7
Technical specifications of motor reactors, 3 AC 380 V – 480 V, Part 1
Order number
Suitable for Power Module
Suitable for Motor Module
Unit rating of Power Module or
Motor Module
Rated current
Power loss
- at 50 Hz
- at 150 Hz
Connections
- to the Power Module or Motor
Module
- Load
- PE
Max. permissible cable length
between motor reactor and motor
- with 1 motor reactor
- with 2 motor reactors in series
Degree of protection
Dimensions
Width
Height
Depth
Weight, approx.
180
6SL3000-
2BE32-1AA0
6SL3315-
1TE32-1AAx
6SL3325-
1TE32-1AAx
kW
110
A
210
kW
0.436
kW
0.486
M10
M10
M8
m
m
IP00
mm
300
mm
285
mm
257
kg
66
2BE32-6AA0
2BE33-2AA0
1TE32-6AAx
1TE33-1AAx
1TE32-6AAx
1TE33-1AAx
132
260
0.454
0.422
0.5
0.47
M10
M10
M10
M10
M8
300 (shielded) / 450 (non-shielded)
525 (shielded) / 787 (non-shielded)
IP00
IP00
300
315
277
66
Chassis Liquid Cooled Power Units
Manual, (GH7), 01/2011, 6SL3097-4AM00-0BP1
2BE35-0AA0
1TE35-0AAx
1TE35-0AAx
160
250
310
490
0.448
0.5
M12
M12
M8
M8
IP00
300
300
285
365
257
277
66
100

Advertisement