To Update Control Software (Motor Ctrl) - Garland MWE2W Installation, Operation & Service Manual

1 & 2 platen electric & gas clamshell grills with product recognition
Table of Contents

Advertisement

GARLAND CLAMSHELL GRILLS WITH PRODUCT RECOGNITION
TO UPDATE CONTROL SOFTWARE (main control)
3. Enter programming mode by:
a. PRESS AND HOLD the TEMP & CLOCK
buttons on the control. Turn main power
switch on WHILE HOLDING two buttons
in. Hold for approximately 3 seconds.
Control will turn on as normal.
b. Turm manin
power switch
OFF and wait for
10 seconds.
c. Turm main switch ON. Control should
read something similar to "MOD BOOT"
4. Begin Uploading software by:
a. Press ZipGraders BLUE button.
b. Monitor Serial Link and preogress LED's
as indicated on the back of the ZipGrader.
PART #4527466 (12 Aug 2011)
INSTALLATION/OPERATION & SERVICE MANUAL - 1&2 PLATEN
5. Control upgrade
is complete when
the control displays
FULL DEFAULT and
then returns to the
OFF position. WAIT
FOR THE ZIPGRAD-
ER TO AUTOMATI-
CALLY TURN OFF.
6. Turn main power switch OFF.
7. Remove RJ12 telephone cable from control,
and insert into additional controls. Repeat
step 4 through 7 until complete.
TO UPDATE CONTROL
SOFTWARE (motor control)
1. Remove upper
pushbutton panel
and lower control
panel.
a. Remove upper
panel screws to
release upper
panel.
b. Carefully lower
upper panel and
remove lower
control panel
screws on both
left and right
sides.
c. Remove kick panel and place on fl oor.
d. Disconnect connector plugs to allow for
relocation of the lower control panel. Do
not disconnect main power switch plug
for later use.